The KMs and ETLs developed by Sentry Software leverage the instrumentation layer provided by the manufacturers to collect hardware and storage information. Depending on the platform to be monitored, specific roles and permissions may be required for the user account used to monitor the systems. Refer to the table below to know the roles and permissions required for the most common manufacturers and systems:
Model | Example | Protocol | Default Port | Minimum Role Required | Sentry Software's Products | Additional Notes |
---|---|---|---|---|---|---|
Dell Compellent | SC9000 | HTTPS | 3033 | Reporter |
|
KB1266 |
Dell Compellent | SC9000 | WBEM | 5989 | Administrator |
|
|
Dell EMC Isilon | - | REST | 8080 | Audit Admin |
|
KB1250 |
Dell EMC PowerStore | 1000T | REST | 443 | Operator |
|
|
Dell EMC Unity | 300F | WBEM | 5989 | Operator |
|
|
Dell EMC Unity | 300F | REST | 443 | Operator |
|
|
Dell EMC Symmetrix/VNX | VMAX250F | WBEM | 5989 | Monitor |
|
KB1052 |
Dell EMC Symmetrix/PowerMax (incl. V4) | VMAX250F | REST | 8443 | Monitor |
|
|
Dell EMC VNX | VNX5300 | WBEM | 5989 | Monitor |
|
KB1205 |
Dell EMC ScaleIO | - | REST | 443 | Monitor |
|
Account must be created via SSH on the Metadata Manager, e.g. scli --set_password --username user --mdm_ip 10.0.10.110 |
Dell EMC Xtremio | - | HTTPS | 443 | Read Only |
|
|
Fujitsu Eternus AF/DX Series |
|
HTTPS | 5665 | Monitor |
|
|
Hitachi G series | G200 | WBEM | 5989 | Storage Administrator (View Only) |
|
|
Hitachi G series | G200/G350 | REST | 23451 | Storage Administrator (View Only) |
|
KB1181 |
HP MSA P2000 G3 | MSA P2000 G3 | WBEM | 5989 | Manage |
|
SMI-S access is required. By default, only the "manage" role has SMI-S access. |
HP 3PAR | 7200 | WBEM | 5989 | Browse |
|
KB1094 |
IBM V7000 Unified | 2076-112 | WBEM | 5989 | Monitor |
|
|
IBM SVC | 2145-CF8 | WBEM | 5989 | Monitor |
|
KB1280 |
IBM XiV | - | Read Only |
|
|||
IBM HMC | DS8882F | WBEM | 6989 | Viewer |
|
|
NetApp Active IQ Unified Manager | FAS2650 | REST | 443 | Operator |
|
|
NetApp E-Series | netapp-e2824 | REST | 8443 | Monitor |
|
|
NetApp ONTAP | FAS2650 | REST | 443 | Read Only |
|
|
Pure | FlashArray/M10 R2 | HTTPS | 443 | Read Only |
|
KB1288 |
RedHat Ceph | - | HTTP | 7000 | Read Only |
|
Related Topics
- Determining the .si Adapter to Use to Monitor Pure Storage Systems with the Storage Analyzer KM
- Storage Analyzer KM: Verifying Prerequisites (Credentials and Connectivity)
- Monitoring Dell Compellent Systems with Hardware Sentry
- Integrating in TrueSight KMs that are not CMA-Compatible
- Handling PATROL Events Generated by Sentry KMs in BMC Helix Operations Manager