Required Roles and Permissions for Hardware and Storage Monitoring

This articles outlines the roles or permissions required to monitor Dell EMC, Hitachi, HP, IBM, NetApp, Pure, and RedHat systems.

Related Topics

The KMs and ETLs developed by Sentry Software leverage the instrumentation layer provided by the manufacturers to collect hardware and storage information. Depending on the platform to be monitored, specific roles and permissions may be required for the user account used to monitor the systems. Refer to the table below to know the roles and permissions required for the most common manufacturers and systems:

Model Example Protocol Default Port Minimum Role Required Sentry Software's Products Additional Notes
Dell Compellent SC9000 HTTPS 3033 Reporter
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
KB1266
Dell Compellent SC9000 WBEM 5989 Administrator
  • BMC Discovery (Dell Compellent Enterprise Manager pattern)
Dell EMC Isilon - REST 8080 Audit Admin
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (EMC Isilon REST pattern)
KB1250
Dell EMC PowerStore 1000T REST 443 Operator
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery
Dell EMC Unity 300F WBEM 5989 Operator
  • Hardware Sentry KM
Dell EMC Unity 300F REST 443 Operator
  • Storage Analyzer KM
  • Storage All-in-One ETL
Dell EMC Symmetrix/VNX VMAX250F WBEM 5989 Monitor
  • EMC Disk Arrays KM
  • Hardware Sentry KM
  • EMC Disk Arrays KM
  • BMC Discovery (EMC Symmetrix, CLARRiiON and VNX pattern)
KB1052
Dell EMC Symmetrix/PowerMax (incl. V4) VMAX250F REST 8443 Monitor
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
Dell EMC VNX VNX5300 WBEM 5989 Monitor
  • EMC Disk Arrays KM
  • Hardware Sentry KM
  • EMC SMI-S Agent ETL
  • BMC Discovery (EMC Symmetrix, CLARRiiON and VNX pattern)
KB1205
Dell EMC ScaleIO - REST 443 Monitor
  • Storage Analyzer KM
  • Storage All-in-One ETL
  • BMC Discovery (Dell EMC ScaleIO/VxFlex/PowerFlex pattern)
Account must be created via SSH on the Metadata Manager, e.g. scli --set_password --username user --mdm_ip 10.0.10.110
Dell EMC Xtremio - HTTPS 443 Read Only
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (Dell EMC Xtremio pattern)
Fujitsu Eternus AF/DX Series
  • AF S3
  • DX S5
  • DX8100 S4
  • DX8900 S4
HTTPS 5665 Monitor
  • Storage Analyzer KM
  • Storage All-in-One ETL
Hitachi G series G200 WBEM 5989 Storage Administrator (View Only)
  • Hitachi Disk Arrays KM
  • Hardware Sentry KM
  • Hitachi Device Manager ETL
  • BMC Discovery (XtremIO Rest pattern)
Hitachi G series G200/G350 REST 23451 Storage Administrator (View Only)
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
KB1181
HP MSA P2000 G3 MSA P2000 G3 WBEM 5989 Manage
  • Hardware Sentry KM
  • BMC Discovery (HP MSA pattern)
SMI-S access is required. By default, only the "manage" role has SMI-S access.
HP 3PAR 7200 WBEM 5989 Browse
  • HP 3PAR KM
  • HP 3PAR ETL
  • BMC Discovery (HP 3PAR pattern)
KB1094
IBM V7000 Unified 2076-112 WBEM 5989 Monitor
  • IBM SVC-Storwize KM
  • Hardware Sentry KM
  • IBM SVC-Storwize ETL
  • BMC Discovery (IBM Storwize pattern)
IBM SVC 2145-CF8 WBEM 5989 Monitor
  • IBM SVC-Storwize KM
  • Hardware Sentry KM
  • IBM SVC-Storwize ETL
  • BMC Discovery (IBM Storwize pattern)
KB1280
IBM XiV - Read Only
  • IBM XiV KM
  • Hardware Sentry KM
  • IBM XiV ETL
  • BMC Discovery (IBM XiV pattern)
IBM HMC DS8882F WBEM 6989 Viewer
  • IBM DS6000, DS8000 Series KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (IBM DS68 pattern)
NetApp Active IQ Unified Manager FAS2650 REST 443 Operator
  • Storage Analyzer KM
  • Storage All-in-One ETL
  • BMC Discovery (NetApp Storage Active IQ Unified Manager pattern)
NetApp E-Series netapp-e2824 REST 8443 Monitor
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (NetApp E-Series pattern)
NetApp ONTAP FAS2650 REST 443 Read Only
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (NetApp Storage (REST API) pattern)
Pure FlashArray/M10 R2 HTTPS 443 Read Only
  • Storage Analyzer KM
  • Hardware Sentry KM
  • Storage All-in-One ETL
  • BMC Discovery (Pure Storage pattern)
KB1288
RedHat Ceph - HTTP 7000 Read Only
  • Storage Analyzer KM
  • Storage All-in-One ETL