Problem
Data might not be collected for HPE XP7/XP8 storage systems in TrueSight Capacity Optimization or TrueSight Operations Management if the disk array receives too many concurrent requests. When this issue occurs, the following exception appears in the Debug Log:
INFO : 2021/06/25 11:15:00 IST ; Thread 370207 ; HDS ; com.sentrysoftware.portal.common.job.interruption.ControlledExecution ; $Revision$ ; doRun
| EXCEPTION WBEMException : Task com.ws.wbem.jserver.utils.WBEMExecutor@19c54be rejected from java.util.concurrent.ThreadPoolExecutor@67fbc6[Running, pool size = 100, active threads = 100, queued tasks = 0, completed tasks = 446832]
and a Netstat query to the SMI-S provider shows a large number of connections in a “CLOSE_WAIT” state:
Solution
For TrueSight Capacity Optimization: Increase the service period from 90000 to 7200000
-
Access the BMC Truesight Capacity Optimization Console
-
Navigate to Administration > ETL & SYSTEM TASKS > ETL Tasks
-
Choose the affected ETL task
-
Under Run Configurations, click the icon to edit the run configuration
-
Click Advanced
-
Click the link You can manually edit ETL properties from this page located at the bottom of the page
-
Set the service.period to 7200000
-
Save your changes.
-
Restart the SMI-S Provider to initiate data collection.
For TrueSight Operations Management: Increase the polling interval to 1h, and Discovery interval to 24h
-
Access the BMC Truesight Operations Management Console
-
In the navigation pane, expand Configuration and select Infrastructure Policies
-
In the Infrastructure Policies page, locate the monitoring policy you wish to modify, click its action button and click Edit.
-
In the Edit Monitoring Policy page, locate the Storage Monitoring Solution and click its action button to access the monitoring options panel
-
Click the action button of the affected device and choose Edit
-
Under Optional Settings, set the Polling Interval to 60 minutes, and the Discovery Interval to 1440 minutes (24 hours).
-
Restart the SMI-S Provider to initiate data collection.
If issues persist after increasing the polling intervals or service period, contact the HPE/Hitachi Support.
Related Topics
- Troubleshooting Issues Related to the Hitachi G-Series and HUS-VM Embedded SMI-S Providers
- Determining the .si Adapter to Use to Monitor Pure Storage Systems with the Storage Analyzer KM
- Monitoring Remote Windows Hosts Without Credentials
- KMs Report "Collection Hub is not started. Cannot send the query"
- How to Monitor Hitachi E and G Series Storage Systems with Storage Analyzer KM