Description
When configuring the Hardware Sentry KM to monitor a system running on Linux using SNMP-based connectors such as "Dell OpenManage Server Administrator" or "HP Insight Management Agent - Server", you may get the following error message:
SNMP TEST on ankara: FAILED
---------------------
The SNMP 'get_next' request failed:
- Host: ankara
- Community: public
- OID:1.3.6.1.4.1.674.10892.1.300.10.1
- errno: 100
If after double-checking that the SNMP test actually fails with the third-party utility snmpwalk and making sure that the system management solution is properly installed and that the snmp daemon is also running, you will have to verify that there is not a configuration problem in your /etc/snmp/snmpd.conf file which prevents the KM/snmpwalk from querying some specific OID’s.
Procedure
- Open /etc/snmp/snmpd.conf in a text editor
- Search for the view all included .1
- Uncomment the line view all included .1
- Only allow the specific OIDs that are used by the KM:view systemview included .1.3.6.1.2.1.1
view systemview included .1.3.6.1.2.1.25.1.1
view systemview included .1.3.6.1.4.1.674.10892
view systemview included .1.3.6.1.4.1.674.10893 - Save your changes.
- Restart the snmp daemon:[root@ankara ~]# /etc/init.d/snmpd restart
Stopping snmpd: [ OK ]
Starting snmpd: [ OK ] - Perform the SNMP test again. The report should now show:
SNMP TEST on ankara: SUCCEEDED
------------------------------
The SNMP 'get_next' request completed successfully:
- Host: ankara
- Community: public
- OID:1.3.6.1.4.1.674.10892.1.300.10.1
- Value:1.3.6.1.4.1.674.10892.1.300.10.1.1.1 integer 1For local monitoring (i.e., PATROL Agent installed on the monitored server), please check that the KM is allowed to communicate with the SNMP agent using at least a read-only community string. You may have to add the following permission in your snmpd.conf, if you have ACL 's implemented rocommunity M0n1t0ring 127.0.0.1
Related Topics
- Unable to Monitor Hardware Using SNMP-based Connectors with PATROL Agent v.9.5.00.02
- All SNMP-based Connectors Fail for one Hour before Reactivating
- SNMP 'get_next' fails on Network adapter on HP ProLiant Servers
- Instances are Missing Even Though Connectors Are Properly Loaded
- No Storage Connector Activating when Monitoring Dell Servers