Description
Hardware Sentry KM and BPM Express for Hardware discover only a subset of the processors and memory modules on Sun Fire M8000 and M9000 machines because it does not handle properly the different CPU and memory boards in these high-end systems.
Symptoms
In the PATROL Console, Hardware Sentry KM will display icons for 4 or 8 processors while the machine actually is equipped with more (8, 16, 24 or 32 processors).
In BMC Portal, BMC Performance Manager Express for Hardware will display instances for 4 or 8 processors while the machine actually is equipped with more (8, 16, 24 or 32 processors).
No error message is displayed.
Solution
- Patch P1086 fixes the problem in Hardware Sentry KM version 1.6.00. It is recommended that users of versions 1.5.00 and 1.5.01 upgrade to version 1.6.00 and apply this patch.
- Patch P1087 fixes the problem in BMC Performance Manager Express for Hardware version 2.7.00. It is recommended that users of version 2.6.00 upgrade to the version 2.7.00 and apply this patch.
Related Topics
- Hardware Monitoring: Non-physical Network Cards Displayed on Sun Solaris Systems
- Hardware Monitoring: Physical Network Cards not Discovered on Sun Solaris Systems
- Monitoring Sun StorageTek Disk Arrays with Hardware Sentry
- Monitoring Sun Fire F12K, F15K, E20K and E25K Servers with Hardware Sentry
- Monitoring Sun Fire M4000, M5000, M8000 and M9000 Servers with Hardware Sentry