Description
The Tuning thresholds mechanism relies on PATROL internal features to set thresholds (also called “Parameter Overrides” or “Tuning”). A PATROL Agent version 3.4.11 or higher is required.
Thresholds can be applied to a single instance of a class (instance-specific) or to all instances of a single class (such thresholds are called global and are referred to as “ALL_INSTANCES thresholds”). When both types of thresholds are applied to a parameter, the single instance thresholds take precedence over the ALL_INSTANCES thresholds.
Applying Thresholds to a Single Instance
Thresholds apply to the instance specified by the configuration variable path.
Configuration Variable Path
Thresholds are set in the following configuration variable:
/___tuning___/<class name>/<object ID>/<parameter name>
Example
/___tuning___/MS_HW_FAN/MS_HW_DellOpenManagehdflocalhost_11/Speed
This variable contains the thresholds that apply to the “Speed” parameter of the “MS_HW_DellOpenManagehdflocalhost_11” PATROL instance of the MS_HW_FAN class.
Variable Format
The format of the variable is:
# | Example | Content definition |
1 | 1 | Parameter activation (0 = inactive, 1 = active) |
2 | 31 | History retention period (in days) |
3 | -1 | Polling interval in seconds. Set to -1 if not a collector |
4 | 0 | Border activation (0 = inactive, 1 = active) |
5 | 0 | Border minimum threshold |
6 | 0 | Border maximum threshold |
7 | VOID | Border alarm type |
8 | 1 | Alarm 1 activation (0 = inactive, 1 = active) |
9 | 1 | Alarm 1 minimum threshold |
10 | 1 | Alarm 1 maximum threshold |
11 | WARN | Alarm 1 type |
12 | 1 | Alarm 2 activation (0 = inactive, 1 = active) |
13 | 2 | Alarm 2 minimum threshold |
14 | 2 | Alarm 2 maximum threshold |
15 | ALARM | Alarm 2 type |
16 | 1 | Border trigger type (immediately, after n times, after all recovery actions have failed) |
17 | 1 | Border Max number of occurences (n times) |
18 | 1 | Alarm 1 trigger type (immediately, after n times, after all recovery actions have failed) |
19 | 1 | Alarm 1 Max number of occurences (n times) |
20 | 1 | Alarm 2 trigger type (immediately, after n times, after all recovery actions have failed) |
21 | 1 | Alarm 2 Max number of occurences (n times) |
Example
Tresholds that immediately trigger a warning if value is 1 and an alarm if value is 2.
1, 31, -1, 0, 0, 0, VOID, 1, 1, 1, WARN, 1, 2, 2, ALARM, 1, 1, 1, 1, 1, 1, EOD
Applying Thresholds to all Instances of a Parameter
Configuration Variable Path
Thresholds are set in the following configuration variable:
/___tuning___/<class>/ALL_INSTANCES/<parameter>
Example
/___tuning___/MS_HW_FAN/ALL_INSTANCES/Speed
This variable contain the thresholds that apply to all instances of the “Speed” parameter of the MS_HW_FAN class.
Variable Format
The content of the variable is identical to the content of the single instance thresholds variable.
Important Note: “Tuning” thresholds in the agent’s configuration are not taken into account immediately, but only when the corresponding instances are created. You need to restart the PATROL Agent for the new “Tuning” thresholds to take effect.