On IBM xSeries Servers, IBM Director 5.20 or Later Will not Work After Upgrade

Due to a problem in its upgrade procedure, the IBM Director Agent stops working, preventing Hardware Sentry KM and BMC Performance Manager Express for Hardware from monitoring the IBM xSeries server.

Related Topics

Description

On IBM xSeries Servers running Windows, IBM Director 5.20.x / 6.10.x will not work after upgrading from 5.10.x or earlier. As a result, "missing device" and "failed connector" alerts are generated by Hardware Sentry KM or BMC Performance Manager Express for Hardware.

Symptoms

A process called Pegasus Provider Adapter (ppa.exe) is still running after the upgrade.

Solution

Attempt a reinstall of the new IBM Director. If this does not work, reinstall the old version, uninstall it (do not upgrade directly) then reinstall the new version.